What Error Code 02 Means on a Kenmore Ice Maker
Error code 02 on standalone Kenmore ice maker units indicates a water inlet valve or water sensor failure. The unit cannot draw water to make ice.
Common Causes
- Failed water inlet valve solenoid
- Blocked inlet screen (mineral deposits)
- Low water pressure
- Water level sensor failure
What You Can Do
- Ensure the water reservoir (if portable unit) is filled to the max line.
- For plumbed units, check that water pressure meets minimum requirements (20 psi).
- Inspect the inlet valve screen for mineral buildup — clean with white vinegar.
- If valve replacement is needed, a technician can confirm with a solenoid resistance test.